X Ray Nondestructive Generator 300 Kv Rt Flaw Detector
This device uses ceramic X-ray tubes to meet the needs of on-site X-ray transmission inspection operations, achieving high energy, small and lightweight, continuous exposure, and automated operation. It also adopts a gas insulated anode grounding method, making it a fully automatic X-ray transmission inspection device.
The controller adopts a user-friendly interface, with a unique LED Chinese font status display. The parameter adjustment uses an industrial stepless knob method, making it eye-catching and quick to adjust. The internal circuit is of modular structure, with high reliability and easy disassembly and maintenance. The fully automatic training machine mode with generator discharge automatic voltage reduction effectively protects the lifespan of the X-ray tube. Accurate fault detection, convenient for users to use and maintain.
Industry leading MIXN series expert intelligent X-ray control system with high intensity anti-interference;
Modular main circuit structure, duct type heat dissipation, continuous operation with high reliability;
The industrial stepless knob is used for time and kilovolt adjustment, which is fast, convenient, and reliable;
Specifications
| Project | RD-300LGD | |
| input | Input power |
Single-phase 50Hz AC220V - 250V
|
| Power supply capacity |
≥ 2.8 KVA
|
|
| output | X - ray tube voltage | 150-300 KVp |
| X ray tube current | 5mA | |
| mA Stability degree | ± 1% | |
| Ray tube | Focal size |
2.6× 2.6
|
| X-ray irradiation range |
45°±5°
|
|
| Ray generator |
working pressure Cooling mode Insulation way |
0.45MPa ~ 0.5Mpa Anode ground connection radiator Strong wind cold Gas insulation SF6 |
|
Size weight (kg) |
Φ350×885
|
|
| 46 | ||
| Maximum penetration | Thickness steel A3(mm) | 80 mm Fe(5 min) |
| condition | focal distance 600mm ,Agfa film,Double lead foil,Liquid temperature 22,Film density ≥1.5 | |
| sensitivity | superior 2% | |
| controller |
Size weight Circuit |
325×270×180 < 9(kg) Automatic control and protection |
| Environment |
working temperature relative humidity Altitude |
-30°~ +40° Not more than 85% Not higher 1500m |
| methods | Maximum one-time startup time ≤ 90 minutes | |
| Insulation level | E | |
| protection grade | IP51 | |
| Executive standards |
GB/T26838-2011
|
|
![]()
![]()